Legrand

Display: 1-24 from 51 products

1
UPS Legrand Inform 800VA Line-interactive GUARDIAN LCD 800AP
  • Brand: Legrand
Microprocessor controlled Line Interactive Technology
Boost and Buck Automatic Voltage Regulation (AVR)
LCD or LED Display Panel
Advanced Battery Management (ABM)
Input Frequency auto sensing ( 50/60 Hz )
Auto restart after mains recovery
Charging during switched off mode
Short circuit and overload protection
Cold Start Function
USB Communication Interface and Remote Monitoring Software*
Modem/Phone line protection*
Compact size and user friendly operation
*Available at AP models only

Read more
99,89 EUR 85.88 EUR VAT included
The product is in stock
-14%
Details
2
UPS Legrand Inform 1KVA Line-interactive GUARDIAN LCD 1000AP
  • Brand: Legrand
Microprocessor controlled Line Interactive Technology
Boost and Buck Automatic Voltage Regulation (AVR)
LCD or LED Display Panel
Advanced Battery Management (ABM)
Input Frequency auto sensing ( 50/60 Hz )
Auto restart after mains recovery
Charging during switched off mode
Short circuit and overload protection
Cold Start Function
USB Communication Interface and Remote Monitoring Software*
Modem/Phone line protection*
Compact size and user friendly operation
*Available at AP models only

Read more
135.93 EUR VAT included
The product is in stock
Details
3
UPS Legrand Inform 1,5KVA Line-interactive GUARDIAN LCD 1500AP
  • Brand: Legrand
Microprocessor controlled Line Interactive Technology
Boost and Buck Automatic Voltage Regulation (AVR)
LCD or LED Display Panel
Advanced Battery Management (ABM)
Input Frequency auto sensing ( 50/60 Hz )
Auto restart after mains recovery
Charging during switched off mode
Short circuit and overload protection
Cold Start Function
USB Communication Interface and Remote Monitoring Software*
Modem/Phone line protection*
Compact size and user friendly operation
*Available at AP models only

Read more
185.97 EUR VAT included
The product is in stock
Details
4
UPS Legrand Inform 2KVA Line-interactive GUARDIAN LCD 2000AP
  • Brand: Legrand
Microprocessor controlled Line Interactive Technology
Boost and Buck Automatic Voltage Regulation (AVR)
LCD or LED Display Panel
Advanced Battery Management (ABM)
Input Frequency auto sensing ( 50/60 Hz )
Auto restart after mains recovery
Charging during switched off mode
Short circuit and overload protection
Cold Start Function
USB Communication Interface and Remote Monitoring Software*
Modem/Phone line protection*
Compact size and user friendly operation
*Available at AP models only

Read more
212.00 EUR VAT included
The product is in stock
Details
5
UPS Legrand Inform Line-interactive Inf -C 1000 Compact 1000VA
  • Brand: Legrand
Pure Sinewave Output for any critical load
User Friendly LCD Display
Boost and buck Automatic Voltage Regulation
97% High Effciency in Normal Mode
Communication Port and Remote Monitoring Software
Overload and Short Circuit Protection
Advanced Battery Management
Discharge Protection
Fault Alarms and State Warnings
Cold Start Function
Compact size, light weight and low noise
Read more
300.08 EUR VAT included
The product is in stock
Details
6
UPS Legrand Inform Line-interactive Inf -C 2000 Compact 2000VA
  • Brand: Legrand
Pure Sinewave Output for any critical load
User Friendly LCD Display
Boost and buck Automatic Voltage Regulation
97% High Effciency in Normal Mode
Communication Port and Remote Monitoring Software
Overload and Short Circuit Protection
Advanced Battery Management
Discharge Protection
Fault Alarms and State Warnings
Cold Start Function
Compact size, light weight and low noise
Read more
400.17 EUR VAT included
The product is in stock
Details
7
UPS Legrand Inform Line-interactive Inf-C3000 Compact 3000VA
  • Brand: Legrand
Pure Sinewave Output for any critical load
User Friendly LCD Display
Boost and buck Automatic Voltage Regulation
97% High Effciency in Normal Mode
Communication Port and Remote Monitoring Software
Overload and Short Circuit Protection
Advanced Battery Management
Discharge Protection
Fault Alarms and State Warnings
Cold Start Function
Compact size, light weight and low noise
Read more
508.27 EUR VAT included
The product is in stock
Details
8
UPS Legrand Inform 5KVA DSP Multipower DSPMP 1105-000 PM without batteries
  • Brand: Legrand
1 Phase in / 1 Phase out 5kVA to 10kVA,
On-line ‘double conversion’ technology
Real Digital Signal Processor ( DSP ) Controller
Parallel redundant operation up to 4 units
Input Power Factor Correction PFC
High output power factor ( PF : 0.9 )
Low total harmonic distortion (THD) level
Convertible display helps to use both for tower and rack applications
Transformerless Design
Availability to configure as 50/60Hz Frequency Converter from LCD Panel
High Performance with the PWM Sinewave Topology
Cold Start Function
Intelligent Battery Management System extends the life time of batteries
Overload, Overheat & Short Circuit Protections
User Friendly Multi-Functional LED/LCD Display Panel
Energy Saving Mode ( ECOMODE )
Smart Fan Speed Regulation with temperature controlled
RS232 Communication Port & Management Software
Internal SNMP, DRY contact, RS485 card options
Read more
973.70 EUR VAT included
The product is in stock
Details
9
UPS Legrand Inform DSP Multipower DSPMP 1105-005 with batteries
  • Brand: Legrand
1 Phase in / 1 Phase out 5kVA to 10kVA,
On-line ‘double conversion’ technology
Real Digital Signal Processor ( DSP ) Controller
Parallel redundant operation up to 4 units
Input Power Factor Correction PFC
High output power factor ( PF : 0.9 )
Low total harmonic distortion (THD) level
Convertible display helps to use both for tower and rack applications
Transformerless Design
Availability to configure as 50/60Hz Frequency Converter from LCD Panel
High Performance with the PWM Sinewave Topology
Cold Start Function
Intelligent Battery Management System extends the life time of batteries
Overload, Overheat & Short Circuit Protections
User Friendly Multi-Functional LED/LCD Display Panel
Energy Saving Mode ( ECOMODE )
Smart Fan Speed Regulation with temperature controlled
RS232 Communication Port & Management Software
Internal SNMP, DRY contact, RS485 card options
Read more
1332.04 EUR VAT included
The product is in stock
Details
10
UPS Legrand Inform DSP Multipower DSPMP 1106-000 PM without batteries
  • Brand: Legrand
1 Phase in / 1 Phase out 5kVA to 10kVA,
On-line ‘double conversion’ technology
Real Digital Signal Processor ( DSP ) Controller
Parallel redundant operation up to 4 units
Input Power Factor Correction PFC
High output power factor ( PF : 0.9 )
Low total harmonic distortion (THD) level
Convertible display helps to use both for tower and rack applications
Transformerless Design
Availability to configure as 50/60Hz Frequency Converter from LCD Panel
High Performance with the PWM Sinewave Topology
Cold Start Function
Intelligent Battery Management System extends the life time of batteries
Overload, Overheat & Short Circuit Protections
User Friendly Multi-Functional LED/LCD Display Panel
Energy Saving Mode ( ECOMODE )
Smart Fan Speed Regulation with temperature controlled
RS232 Communication Port & Management Software
Internal SNMP, DRY contact, RS485 card options
Read more
973.70 EUR VAT included
The product is in stock
Details
11
UPS LEGRAND Daker Dk On-Line 1kVA IEC Convertible 310050
  • Brand: Legrand
On‑Line double conversion UPS that can be used in both tower and rack configurations
The main parameters of the system and the status of the UPS, including the battery charge level and faults, are displayed on
the LCD screen.
Additional battery cabinets are available to increase the backup time of the UPS. A charger can be added in all battery cabinets for fast, safe charging.
With the reversible screen, the Daker DK UPS can be used in both tower and 19» rack configuration.
The integrated communication software not only controls the UPS and its switch-off if there is a malfunction, and enables the user to test the main functions remotely,communicate via SNMP/Internet/network adaptor and access the functions of the UPS via the Internet, but can also send the user an SMS if specific events occur.
The internal extension connector enables a WEB/SNMP card or a relay interface to be installed which provides insulated contacts for applications on industrial control panels or remote alarm panels.
If there is an electronic fault, overload, overheating or for scheduled maintenance operations, the automatic or manual (optional) bypass ensures continuity of the power supply for critical loads. A bypass switch is available for maintenance.




 
Read more
456.22 EUR VAT included
The product is in stock
Details
12
UPS LEGRAND Daker Dk On-Line 2kVA IEC Convertible 310051
  • Brand: Legrand
On‑Line double conversion UPS that can be used in both tower and rack configurations
The main parameters of the system and the status of the UPS, including the battery charge level and faults, are displayed on
the LCD screen.
Additional battery cabinets are available to increase the backup time of the UPS. A charger can be added in all battery cabinets for fast, safe charging.
With the reversible screen, the Daker DK UPS can be used in both tower and 19» rack configuration.
The integrated communication software not only controls the UPS and its switch-off if there is a malfunction, and enables the user to test the main functions remotely,communicate via SNMP/Internet/network adaptor and access the functions of the UPS via the Internet, but can also send the user an SMS if specific events occur.
The internal extension connector enables a WEB/SNMP card or a relay interface to be installed which provides insulated contacts for applications on industrial control panels or remote alarm panels.
If there is an electronic fault, overload, overheating or for scheduled maintenance operations, the automatic or manual (optional) bypass ensures continuity of the power supply for critical loads. A bypass switch is available for maintenance.


Read more
793.94 EUR VAT included
The product is in stock
Details
13
UPS LEGRAND Daker Dk On-Line 3kVA IEC Convertible 310052
  • Brand: Legrand
On‑Line double conversion UPS that can be used in both tower and rack configurations
The main parameters of the system and the status of the UPS, including the battery charge level and faults, are displayed on
the LCD screen.
Additional battery cabinets are available to increase the backup time of the UPS. A charger can be added in all battery cabinets for fast, safe charging.
With the reversible screen, the Daker DK UPS can be used in both tower and 19» rack configuration.
The integrated communication software not only controls the UPS and its switch-off if there is a malfunction, and enables the user to test the main functions remotely,communicate via SNMP/Internet/network adaptor and access the functions of the UPS via the Internet, but can also send the user an SMS if specific events occur.
The internal extension connector enables a WEB/SNMP card or a relay interface to be installed which provides insulated contacts for applications on industrial control panels or remote alarm panels.
If there is an electronic fault, overload, overheating or for scheduled maintenance operations, the automatic or manual (optional) bypass ensures continuity of the power supply for critical loads. A bypass switch is available for maintenance.


Read more
968.70 EUR VAT included
The product is in stock
Details
14
UPS LEGRAND Daker Dk On-Line 4,5kVA Convertible 310053
  • Brand: Legrand
On‑Line double conversion UPS that can be used in both tower and rack configurations
The main parameters of the system and the status of the UPS, including the battery charge level and faults, are displayed on
the LCD screen.
Additional battery cabinets are available to increase the backup time of the UPS. A charger can be added in all battery cabinets for fast, safe charging.
With the reversible screen, the Daker DK UPS can be used in both tower and 19» rack configuration.
The integrated communication software not only controls the UPS and its switch-off if there is a malfunction, and enables the user to test the main functions remotely,communicate via SNMP/Internet/network adaptor and access the functions of the UPS via the Internet, but can also send the user an SMS if specific events occur.
The internal extension connector enables a WEB/SNMP card or a relay interface to be installed which provides insulated contacts for applications on industrial control panels or remote alarm panels.
If there is an electronic fault, overload, overheating or for scheduled maintenance operations, the automatic or manual (optional) bypass ensures continuity of the power supply for critical loads. A bypass switch is available for maintenance.
Read more
1684.36 EUR VAT included
The product is in stock
Details
15
UPS LEGRAND Daker Dk On-Line 6kVA Convertible 310054
  • Brand: Legrand
On‑Line double conversion UPS that can be used in both tower and rack configurations
The main parameters of the system and the status of the UPS, including the battery charge level and faults, are displayed on
the LCD screen.
Additional battery cabinets are available to increase the backup time of the UPS. A charger can be added in all battery cabinets for fast, safe charging.
With the reversible screen, the Daker DK UPS can be used in both tower and 19» rack configuration.
The integrated communication software not only controls the UPS and its switch-off if there is a malfunction, and enables the user to test the main functions remotely,communicate via SNMP/Internet/network adaptor and access the functions of the UPS via the Internet, but can also send the user an SMS if specific events occur.
The internal extension connector enables a WEB/SNMP card or a relay interface to be installed which provides insulated contacts for applications on industrial control panels or remote alarm panels.
If there is an electronic fault, overload, overheating or for scheduled maintenance operations, the automatic or manual (optional) bypass ensures continuity of the power supply for critical loads. A bypass switch is available for maintenance.
Read more
1824.49 EUR VAT included
The product is in stock
Nou
Details
16
UPS LEGRAND Daker Dk On-Line 4,5kVA Without Convertible Batteries 310056
  • Brand: Legrand
On‑Line double conversion UPS that can be used in both tower and rack configurations
The main parameters of the system and the status of the UPS, including the battery charge level and faults, are displayed on
the LCD screen.
Additional battery cabinets are available to increase the backup time of the UPS. A charger can be added in all battery cabinets for fast, safe charging.
With the reversible screen, the Daker DK UPS can be used in both tower and 19» rack configuration.
The integrated communication software not only controls the UPS and its switch-off if there is a malfunction, and enables the user to test the main functions remotely,communicate via SNMP/Internet/network adaptor and access the functions of the UPS via the Internet, but can also send the user an SMS if specific events occur.
The internal extension connector enables a WEB/SNMP card or a relay interface to be installed which provides insulated contacts for applications on industrial control panels or remote alarm panels.
If there is an electronic fault, overload, overheating or for scheduled maintenance operations, the automatic or manual (optional) bypass ensures continuity of the power supply for critical loads. A bypass switch is available for maintenance.
Read more
1363.67 EUR VAT included
The product is in stock
Details
17
UPS LEGRAND Daker Dk On-Line 6kVA Without Convertible Batteries 310057
  • Brand: Legrand
On‑Line double conversion UPS that can be used in both tower and rack configurations
The main parameters of the system and the status of the UPS, including the battery charge level and faults, are displayed on
the LCD screen.
Additional battery cabinets are available to increase the backup time of the UPS. A charger can be added in all battery cabinets for fast, safe charging.
With the reversible screen, the Daker DK UPS can be used in both tower and 19» rack configuration.
The integrated communication software not only controls the UPS and its switch-off if there is a malfunction, and enables the user to test the main functions remotely,communicate via SNMP/Internet/network adaptor and access the functions of the UPS via the Internet, but can also send the user an SMS if specific events occur.
The internal extension connector enables a WEB/SNMP card or a relay interface to be installed which provides insulated contacts for applications on industrial control panels or remote alarm panels.
If there is an electronic fault, overload, overheating or for scheduled maintenance operations, the automatic or manual (optional) bypass ensures continuity of the power supply for critical loads. A bypass switch is available for maintenance.
Read more
1422.92 EUR VAT included
The product is in stock
Details
18
UPS LEGRAND Daker Dk On-Line 10kVA Without Convertible Batteries 310058
  • Brand: Legrand
On‑Line double conversion UPS that can be used in both tower and rack configurations
The main parameters of the system and the status of the UPS, including the battery charge level and faults, are displayed on
the LCD screen.
Additional battery cabinets are available to increase the backup time of the UPS. A charger can be added in all battery cabinets for fast, safe charging.
With the reversible screen, the Daker DK UPS can be used in both tower and 19» rack configuration.
The integrated communication software not only controls the UPS and its switch-off if there is a malfunction, and enables the user to test the main functions remotely,communicate via SNMP/Internet/network adaptor and access the functions of the UPS via the Internet, but can also send the user an SMS if specific events occur.
The internal extension connector enables a WEB/SNMP card or a relay interface to be installed which provides insulated contacts for applications on industrial control panels or remote alarm panels.
If there is an electronic fault, overload, overheating or for scheduled maintenance operations, the automatic or manual (optional) bypass ensures continuity of the power supply for critical loads. A bypass switch is available for maintenance.
Read more
1847.51 EUR VAT included
The product is in stock
Details
19
UPS LEGRAND MEGALINE 1250 RACK single-phase, double conversion VFI 310334
  • Brand: Legrand
- Wide input voltage and frequency range
- Operational frequency at 50 or 60 Hz with auto-recognition
- Frequency conversion 50 in - 60 out or vice versa
- Extension of the input frequency range for operation with power-supply units
- Operation in eco mode (energy savings)
- Operation in load waiting mode (on demand protection)
- Adjustable output voltage in 1 volt steps from the front panel
- Low noise level
- Internal and external temperature measurement
- Fan control based on temperature and load
- Pre-set for emergency remote shut-off

General Features
Nominal power (VA) 1250
Active power (W) 875 
Max expandability (VA) 5000
Max expandability (W) 3500
Technology On-line double conversion (VFI-SS-111)
UPS architecture Modular, Expandable, N+X Redundant with 1250 VA power boards in a single cabinet

Input
Input nominal voltage 230 V
Input voltage range 184 V ÷ 264 V at 100% of the load
Minimum network operating voltage 100 V at 50% of the load
THD Input current ‹ 3%
Input Power Factor › 0.99 from 20% of the load
Input frequency 50 Hz / 60 Hz ± 2% autosensing

Output
Output voltage 230 V ± 1%
Output frequency 50 Hz / 60 Hz synchronised
THD Output voltage ‹ 1% with non-linear load
Waveform Sinusoidal
Crest Factor 3,5 : 1
Performance when connected to the mains 92% at 100% of the load
Allowed overload 300% for 1 sec. – 200% for 5 sec. – 150% for 30 sec.

Back up time
Back up time (min) 13
Back up time expandability Yes

Equipment
Bypass Static and Electromechanical, automatic and internally synchronised (due to overload or operating fault)
Signals and Alarms Large 4-line alphanumeric display, multi-colour status indicator, acoustic signal 
Communication Ports no.1 RS 232 port, no.2 logical gates
UPS Communicator Software Can be downloaded free of charge (after requesting the activation code)
Protections:
Electronic protections against overloads, short-circuits and excessive battery discharge.
Operation stops when the back up time ends. In-rush current limiter at start-up. Sensor to connect the neutral cable correctly. Back-feed protection (electrical safety insulation of the input plug during battery-based operation).
EPO contact (complete shutdown in the event of an emergency)
IN/OUT mains connection Standard German / Clamp connector with universal multiple socket outlet
(Italian/German standard)

Mechanical features
Net weight (kg) 23,5 
Dimensions (H x W x D) (mm) 266 x 483 x 582
Installed power boards 1 
Free power expansion slots 3 
Installed battery kits 1 
Free back up time expansion slots 3

Environmental conditions
Operating temperature (°C) 0÷40
Degree of protection IP21
Relative humidity (%) 20÷80 non-condensing
Noise level at 1 m (dBA) ‹ 40
Certifications Standards EN 62040-1, EN 62040-2, EN 62040-3
Read more
1152.67 EUR VAT included
The product is in stock
Details
20
UPS LEGRAND MEGALINE 2500 RACK single-phase, double conversion VFI 310335
  • Brand: Legrand
- Wide input voltage and frequency range
- Operational frequency at 50 or 60 Hz with auto-recognition
- Frequency conversion 50 in - 60 out or vice versa
- Extension of the input frequency range for operation with power-supply units
- Operation in eco mode (energy savings)
- Operation in load waiting mode (on demand protection)
- Adjustable output voltage in 1 volt steps from the front panel
- Low noise level
- Internal and external temperature measurement
- Fan control based on temperature and load
- Pre-set for emergency remote shut-off

General Features
Nominal power (VA) 2500
Active power (W) 1750 
Max expandability (VA) 5000
Max expandability (W) 3500
Technology On-line double conversion (VFI-SS-111)
UPS architecture Modular, Expandable, N+X Redundant with 1250 VA power boards in a single cabinet

Input
Input nominal voltage 230 V
Input voltage range 184 V ÷ 264 V at 100% of the load
Minimum network operating voltage 100 V at 50% of the load
THD Input current ‹ 3%
Input Power Factor › 0.99 from 20% of the load
Input frequency 50 Hz / 60 Hz ± 2% autosensing

Output
Output voltage 230 V ± 1%
Output frequency 50 Hz / 60 Hz synchronised
THD Output voltage ‹ 1% with non-linear load
Waveform Sinusoidal
Crest Factor 3,5 : 1
Performance when connected to the mains 92% at 100% of the load
Allowed overload 300% for 1 sec. – 200% for 5 sec. – 150% for 30 sec.

Back up time
Back up time (min) 13
Back up time expandability Yes

Equipment
Bypass Static and Electromechanical, automatic and internally synchronised (due to overload or operating fault)
Signals and Alarms Large 4-line alphanumeric display, multi-colour status indicator, acoustic signal 
Communication Ports no.1 RS 232 port, no.2 logical gates
UPS Communicator Software Can be downloaded free of charge (after requesting the activation code)
Protections:
Electronic protections against overloads, short-circuits and excessive battery discharge.
Operation stops when the back up time ends. In-rush current limiter at start-up. Sensor to connect the neutral cable correctly. Back-feed protection (electrical safety insulation of the input plug during battery-based operation).
EPO contact (complete shutdown in the event of an emergency)
IN/OUT mains connection Standard German / Clamp connector with universal multiple socket outlet
(Italian/German standard)

Mechanical features
Net weight (kg) 34
Dimensions (H x W x D) (mm) 266 x 483 x 582
Installed power boards 2 
Free power expansion slots 2 
Installed battery kits 2 
Free back up time expansion slots 2

Environmental conditions
Operating temperature (°C) 0÷40
Degree of protection IP21
Relative humidity (%) 20÷80 non-condensing
Noise level at 1 m (dBA) ‹ 40
Certifications Standards EN 62040-1, EN 62040-2, EN 62040-3
Read more
1524.41 EUR VAT included
The product is in stock
Details
21
UPS LEGRAND MEGALINE 3750 RACK single-phase, double conversion VFI 310336
  • Brand: Legrand
- Wide input voltage and frequency range
- Operational frequency at 50 or 60 Hz with auto-recognition
- Frequency conversion 50 in - 60 out or vice versa
- Extension of the input frequency range for operation with power-supply units
- Operation in eco mode (energy savings)
- Operation in load waiting mode (on demand protection)
- Adjustable output voltage in 1 volt steps from the front panel
- Low noise level
- Internal and external temperature measurement
- Fan control based on temperature and load
- Pre-set for emergency remote shut-off

General Features
Nominal power (VA) 3750
Active power (W) 2625 
Max expandability (VA) 5000
Max expandability (W) 3500
Technology On-line double conversion (VFI-SS-111)
UPS architecture Modular, Expandable, N+X Redundant with 1250 VA power boards in a single cabinet

Input
Input nominal voltage 230 V
Input voltage range 184 V ÷ 264 V at 100% of the load
Minimum network operating voltage 100 V at 50% of the load
THD Input current ‹ 3%
Input Power Factor › 0.99 from 20% of the load
Input frequency 50 Hz / 60 Hz ± 2% autosensing

Output
Output voltage 230 V ± 1%
Output frequency 50 Hz / 60 Hz synchronised
THD Output voltage ‹ 1% with non-linear load
Waveform Sinusoidal
Crest Factor 3,5 : 1
Performance when connected to the mains 92% at 100% of the load
Allowed overload 300% for 1 sec. – 200% for 5 sec. – 150% for 30 sec.

Back up time
Back up time (min) 13
Back up time expandability Yes

Equipment
Bypass Static and Electromechanical, automatic and internally synchronised (due to overload or operating fault)
Signals and Alarms Large 4-line alphanumeric display, multi-colour status indicator, acoustic signal 
Communication Ports no.1 RS 232 port, no.2 logical gates
UPS Communicator Software Can be downloaded free of charge (after requesting the activation code)
Protections:
Electronic protections against overloads, short-circuits and excessive battery discharge.
Operation stops when the back up time ends. In-rush current limiter at start-up. Sensor to connect the neutral cable correctly. Back-feed protection (electrical safety insulation of the input plug during battery-based operation).
EPO contact (complete shutdown in the event of an emergency)
IN/OUT mains connection Standard German / Clamp connector with universal multiple socket outlet
(Italian/German standard)

Mechanical features
Net weight (kg) 43 
Dimensions (H x W x D) (mm) 266 x 483 x 582
Installed power boards 3 
Free power expansion slots 1
Installed battery kits 3
Free back up time expansion slots 1

Environmental conditions
Operating temperature (°C) 0÷40
Degree of protection IP21
Relative humidity (%) 20÷80 non-condensing
Noise level at 1 m (dBA) ‹ 40
Certifications Standards EN 62040-1, EN 62040-2, EN 62040-3
Read more
1894.56 EUR VAT included
The product is in stock
Details
22
UPS LEGRAND MEGALINE 5000 RACK single-phase, double conversion VFI 310337
  • Brand: Legrand
- Wide input voltage and frequency range
- Operational frequency at 50 or 60 Hz with auto-recognition
- Frequency conversion 50 in - 60 out or vice versa
- Extension of the input frequency range for operation with power-supply units
- Operation in eco mode (energy savings)
- Operation in load waiting mode (on demand protection)
- Adjustable output voltage in 1 volt steps from the front panel
- Low noise level
- Internal and external temperature measurement
- Fan control based on temperature and load
- Pre-set for emergency remote shut-off

General Features
Nominal power (VA) 5000
Active power (W) 3500
Max expandability (VA) 5000
Max expandability (W) 3500
Technology On-line double conversion (VFI-SS-111)
UPS architecture Modular, Expandable, N+X Redundant with 1250 VA power boards in a single cabinet

Input
Input nominal voltage 230 V
Input voltage range 184 V ÷ 264 V at 100% of the load
Minimum network operating voltage 100 V at 50% of the load
THD Input current ‹ 3%
Input Power Factor › 0.99 from 20% of the load
Input frequency 50 Hz / 60 Hz ± 2% autosensing

Output
Output voltage 230 V ± 1%
Output frequency 50 Hz / 60 Hz synchronised
THD Output voltage ‹ 1% with non-linear load
Waveform Sinusoidal
Crest Factor 3,5 : 1
Performance when connected to the mains 92% at 100% of the load
Allowed overload 300% for 1 sec. – 200% for 5 sec. – 150% for 30 sec.

Back up time
Back up time (min) 13
Back up time expandability Yes

Equipment
Bypass Static and Electromechanical, automatic and internally synchronised (due to overload or operating fault)
Signals and Alarms Large 4-line alphanumeric display, multi-colour status indicator, acoustic signal 
Communication Ports no.1 RS 232 port, no.2 logical gates
UPS Communicator Software Can be downloaded free of charge (after requesting the activation code)
Protections:
Electronic protections against overloads, short-circuits and excessive battery discharge.
Operation stops when the back up time ends. In-rush current limiter at start-up. Sensor to connect the neutral cable correctly. Back-feed protection (electrical safety insulation of the input plug during battery-based operation).
EPO contact (complete shutdown in the event of an emergency)
IN/OUT mains connection Standard German / Clamp connector with universal multiple socket outlet
(Italian/German standard)

Mechanical features
Net weight (kg) 53
Dimensions (H x W x D) (mm) 266 x 483 x 582
Installed power boards 4
Free power expansion slots -
Installed battery kits 4 
Free back up time expansion slots -

Environmental conditions
Operating temperature (°C) 0÷40
Degree of protection IP21
Relative humidity (%) 20÷80 non-condensing
Noise level at 1 m (dBA) ‹ 40
Certifications Standards EN 62040-1, EN 62040-2, EN 62040-3
Read more
2305.34 EUR VAT included
The product is in stock
Details
23
UPS LEGRAND MEGALINE 1250 single-phase, double conversion VFI 310350
  • Brand: Legrand
Modular UPS redundant and upgradable up to 10kVA with perfomance and functions at the top of their category.
All models have a microprocessor control card that can be configured on the display, by modules powered by 1250 VA each, and by battery kits that contain no. 3x9Ah batteries
The single cabinet and 19 inch rack models issue a power from 1250 to 5000 VA, they can house a maximum of 4 power boards and 4 battery kits. Additional batteries can be stored in specific cabinets, which can be easily connected thanks to an back up time upgrading pre-setting. The range is completed with products made of two cabinets; the first cabinet can house up to 8 power modules, each up to 1250 VA, reaching a maximum power of 10kVA. In the second cabinet it is possible to insert up to 10 battery kits and an additional battery charger. Other battery cabinets identical to the one supplied can be added in order to further upgrade back up time.

Nominal power (VA) 1250 
Active power (W) 875 
Max expandability (VA) 5000 
Max expandability (W) 3500 
Technology On-line double conversion (VFI-SS-111)
UPS architecture Modular, Expandable, N+X Redundant with 1250 VA power boards in a single cabinet

Input
Input nominal voltage 230 V
Input voltage range 184 V ÷ 264 V at 100% of the load
Minimum network operating voltage 100 V at 50% of the load
THD Input current ‹ 3%
Input Power Factor › 0.99 from 20% of the load
Input frequency 50 Hz / 60 Hz ± 2% autosensing

Output
Output voltage 230 V ± 1%
Output frequency 50 Hz / 60 Hz synchronised
THD Output voltage ‹ 1% with non-linear load
Waveform Sinusoidal
Crest Factor 3,5 : 1
Performance when connected to the mains 92% at 100% of the load
Allowed overload 300% for 1 sec. – 200% for 5 sec. – 150% for 30 sec.

Back up time
Back up time (min) 13
Back up time expandability Yes

Equipment
Bypass: Static and Electromechanical, automatic and internally synchronised (due to overload or operating fault).
Signals and Alarms: Large 4-line alphanumeric display, multi-colour status indicator, audio signal
Communication Ports: no.1 RS 232 port, no.2 logical gates
UPS Communicator Software: Can be downloaded free of charge (after requesting the activation code)
Protections:
- Electronic protections against overloads, short-circuits and excessive battery discharge.
- Operation stops when the back up time ends. In-rush current limiter at start-up.
- Sensor to connect the neutral cable correctly.
- Back-feed protection (electrical safety insulation of the input plug during battery-based operation). EPO contact
(complete shutdown in the event of an emergency)
IN/OUT mains connection: Standard German / Clamp connector with universal multiple socket outlet (Italian/German standard)

Mechanical features
Net weight (kg) 23,5 
Dimensions (H x W x D) (mm) 475 x 270 x 570 
Installed power boards 1 
Free power expansion slots 3 
Installed battery kits 1 
Free back up time expansion slots 3 

Environmental conditions
Operating temperature (°C) 0÷40
Degree of protection IP21
Relative humidity (%) 20÷80 non-condensing
Noise level at 1 m (dBA) ‹ 40
Certifications Standards EN 62040-1, EN 62040-2, EN 62040-3
Read more
1035.36 EUR VAT included
The product is in stock
Details
24
UPS LEGRAND MEGALINE 2500 single-phase, double conversion VFI 310352
  • Brand: Legrand
Modular UPS redundant and upgradable up to 10kVA with perfomance and functions at the top of their category.
All models have a microprocessor control card that can be configured on the display, by modules powered by 1250 VA each, and by battery kits that contain no. 3x9Ah batteries
The single cabinet and 19 inch rack models issue a power from 1250 to 5000 VA, they can house a maximum of 4 power boards and 4 battery kits. Additional batteries can be stored in specific cabinets, which can be easily connected thanks to an back up time upgrading pre-setting. The range is completed with products made of two cabinets; the first cabinet can house up to 8 power modules, each up to 1250 VA, reaching a maximum power of 10kVA. In the second cabinet it is possible to insert up to 10 battery kits and an additional battery charger. Other battery cabinets identical to the one supplied can be added in order to further upgrade back up time.

Nominal power (VA) 2500 
Active power (W) 1750 
Max expandability (VA) 5000 
Max expandability (W) 3500 
Technology On-line double conversion (VFI-SS-111)
UPS architecture Modular, Expandable, N+X Redundant with 1250 VA power boards in a single cabinet

Input
Input nominal voltage 230 V
Input voltage range 184 V ÷ 264 V at 100% of the load
Minimum network operating voltage 100 V at 50% of the load
THD Input current ‹ 3%
Input Power Factor › 0.99 from 20% of the load
Input frequency 50 Hz / 60 Hz ± 2% autosensing

Output
Output voltage 230 V ± 1%
Output frequency 50 Hz / 60 Hz synchronised
THD Output voltage ‹ 1% with non-linear load
Waveform Sinusoidal
Crest Factor 3,5 : 1
Performance when connected to the mains 92% at 100% of the load
Allowed overload 300% for 1 sec. – 200% for 5 sec. – 150% for 30 sec.

Back up time
Back up time (min) 13
Back up time expandability Yes

Equipment
Bypass: Static and Electromechanical, automatic and internally synchronised (due to overload or operating fault).
Signals and Alarms: Large 4-line alphanumeric display, multi-colour status indicator, audio signal
Communication Ports: no.1 RS 232 port, no.2 logical gates
UPS Communicator Software: Can be downloaded free of charge (after requesting the activation code)
Protections:
- Electronic protections against overloads, short-circuits and excessive battery discharge.
- Operation stops when the back up time ends. In-rush current limiter at start-up.
- Sensor to connect the neutral cable correctly.
- Back-feed protection (electrical safety insulation of the input plug during battery-based operation). EPO contact
(complete shutdown in the event of an emergency)
IN/OUT mains connection: Standard German / Clamp connector with universal multiple socket outlet (Italian/German standard)

Mechanical features
Net weight (kg) 34 
Dimensions (H x W x D) (mm) 475 x 270 x 570 
Installed power boards 2
Free power expansion slots 2 
Installed battery kits 2 
Free back up time expansion slots 2 

Environmental conditions
Operating temperature (°C) 0÷40
Degree of protection IP21
Relative humidity (%) 20÷80 non-condensing
Noise level at 1 m (dBA) ‹ 40
Certifications Standards EN 62040-1, EN 62040-2, EN 62040-3
Read more
1414.11 EUR VAT included